DOI - Vydavatelství Mendelovy univerzity v Brně

Identifikátory DOI

DOI: 10.11118/978-80-7701-093-1-0168

EVALUATION OF NIRS-ESTIMATION FOR ENZYME-SOLUBLE ORGANIC MATTER (ESOM) IN GRASS SILAGES COMPARED TO THE CELLULASE REFERENCE METHOD

Resch, R.1, Häusler, M.1
1 AREC Raumberg-Gumpenstein, Department Analytics and Forage Evaluation, Raumberg 38, 8952 Irdning-Donnersbachtal, Austria

Enzyme-soluble organic matter (ESOM) of 167 Austrian grass silages was measured using the cellulase reference method, also predicted by near-infrared spectroscopy (NIRS) and a general linear model (GLM) based on chemical parameters. NIRS calibration showed much higher accuracy (R² = 0.90) than GLM (R²=0.57). Results indicate that NIRS is a reliable and cost-effective method for estimating ESOM in grass silage.

Klíčová slova: near-infrared spectroscopy, in vitro digestibility, cellulase-method, calibration

stránky: 168-169, Publikováno: 2026, online: 2026